ALLEN & HEATH MixWizard WZ4 12:2 Guia do Utilizador Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
Allen & Heath 21 WZ
4
16:2 and 12:2 User Guide
Gain Structure
How the levels between the different signal stages are set up is referred to as the gain structure.
For best performance it is important that the connected source signals are matched to the ‘normal
operating level’ of the console. Similarly the levels of the connected amplifiers and destination
equipment should be correctly matched to the console outputs. If set too high then the signal
peaks will be clipped resulting in distortion, and if set too low then the signal-to-noise perfor-
mance will be degraded resulting in excessive background hiss and noise.
Using the Meters
The MixWizard provides metering of inputs and outputs. For best re-
sults operate the console with the main meters averaging around ‘0’ allowing the loudest moments
to reach ‘+6’. Reduce the channel gain settings if the red peak indicators start to flash. Note that
the peak indicators light 5dB before actual clipping to warn that you are nearing distortion and
should reduce gain. The LED bar meters have a ‘quasi-peak’ response with fast attack and slow
release so that fast musical transients are accurately displayed.
Matching a Source to the Console
Start by turning down the channel fader and send
levels to prevent unexpected loud volumes reaching the main speakers and monitors. Using PFL,
adjust the GAIN control for an average ‘0’ reading on the console meters. These automatically
switch to show the channel pre-fade signal when PFL is pressed. Listen to the signal using head-
phones or local AB monitor. Once the channel gain is correctly set you can raise the levels to
bring the channel into the mix. Note that you may need to adjust the gain if you make significant
changes to the EQ. Make sure that any equipment inserted into the channel is set to operate
around 0dBu line level. First set the gain with inserted signal processors such as compressors
switched to bypass.
Matching the Console to Destination Equipment
The console produces a
standard XLR output level of +4dBu for a meter reading of ‘0’. It can produce a maximum of
+26dBu which is more than is usually required and therefore gives you plenty of headroom. If you
are connecting to a sensitive power amplifier it is advisable to turn down its input trim control if
the normal console level is too high. Simply turning down the console output faders degrades the
output stage noise performance and reduces the resolution of the fader movement. The output
faders are best operated around ‘-10’ to ‘0’ for loudest average volume required. This allows addi-
tional headroom if you need it.
Terminology
The normal operating level is the optimum signal level for best console perfor-
mance, indicated by ‘0’ meter readings and resulting in the +4dBu XLR output level. The channels
operate at 0dBu and the mix stages at –2dBu for extended headroom. Headroom is the extra
level available above normal to allow for loud peaks before the signal becomes clipped resulting in
audible distortion. The signal-to-noise ratio (SNR) is the difference measured in dB between nor-
mal level and residual noise floor (hiss) produced by the console electronics. The dynamic range is
the sum of headroom and SNR representing the maximum signal range possible from quietest to
loudest.
Final word
… A little care with setting gain structure throughout the signal chain will give you
the best performance and most manageable control of the mix.
+1
+3
+6
-12
-16
-9
-6
-3
-1
-20
0
+9
-30
-40
-50
-60
-70
-80
-90
+12
+16
+20
SIGNAL-TO-NOISE RATIO
DYNAMIC RANGE
HEADROOM
CLIPPING
NOISE
NORMAL OPERATING RANGE
SIGNAL
!
Vista de página 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 31 32

Comentários a estes Manuais

Sem comentários

Alliance Laundry Systems D677I manuales

Manuales del propietario y guías del usuario para Secadores Alliance Laundry Systems D677I.
Ofrecemos 2 manuales en pdf Alliance Laundry Systems D677I para descargar gratis por tipos de documentos: Manual de usuario


Tabla de contenidos

Clothes Dryer

1

Table of

5

Contents

5

Replacement Parts

7

Important Safety Instructions

10

Installation

11

Nonmetered Models

12

Meter Case

13

Timer Cams

13

Dryer Slide Extension

14

Long Vault Slide Extension

15

Figure 4

16

Figure 5

16

Additional Dryer Security

17

Before You Start

18

Installing the Dryer

19

Supply Pipe

20

Electrical Plug

21

Step 6: Plug In the Dryer

22

Step 7: Check Installation

22

Heat Source Check

23

All Models

24

Manufactured (Mobile) Home

26

Electrical Requirements

27

Figure 17

28

Electrical Connection

29

Three-Wire Connection

30

Four-Wire Power Cord

31

Four-Wire Connection

32

Grounding Instructions

34

Gas Requirements

35

Figure 24

36

Location Requirements

37

Dryer Exhaust Requirements

38

Make-Up Air Requirements

39

Make-Up Air Dos and Don’ts

39

Exhaust Direction

39

Exhaust System

40

Requirements

42

– Inspect Monthly

43

Lint Filter

44

Motor Overload Protector

44

Operation

45

Step 5: Start Dryer

46

Metered Models

46

Operation Instructions for

47

To Insert Money

48

To Insert Card

48

Step 6: Start Dryer

48

Indicator Lights

48

NetMaster Dryers

52

Maintenance

55

If the Dryer:

56

If Service Is Required

57

Secadora de ropa

59

Contenido

63

Piezas de repuesto

65

Instalación

69

Contador de monedas

71

Levas de regulación de tiempo

71

Figura 4

74

Figura 5

74

Seguridad adicional

75

Antes de comenzar

76

Figura 11

78

Figura 12

79

Figura 13

79

Paso 6: Conecte la secadora

80

Paso 7: Revise la instalación

80

Figura 17

86

Figura 20

90

± 1,5 pulgadas

94

Figura 24

95

Requisitos de ubicación

96

Qué hacer y qué no hacer

98

Dirección del escape

98

Sistema de escape

99

DR012A-IN

100

ADVERTENCIA

101

Filtro de pelusa

103

510969 (SP)

104

Operación

105

FABRIC SELECTOR

106

Instrucciones de uso para

107

Luces indicadoras

109

Paso 2: Meta la ropa

110

DRY1926N

111

Figura 57

114

Figura 58

114

Figura 59

114

Mantenimiento

117

Si su secadora:

118

Información de referencia

120

Installer Checklist

122





Más productos y manuales para Secadores Alliance Laundry Systems

Modelos Tipo de documento
512685R2 Manual de usuario   Alliance Laundry Systems 512685R2 User Manual, 50 paginas